That's why some people appear bright until you hear them speak. Hp smart array p812 controller onboard expander firmware was updated to version 3.12 to enforce 3gbps sata connection speeds which is the maximum supported sata data rate on hp smart array p212, p410, p410i, p411, p711m, p712m, and p812 controllers.
![hp smart array p410i controller failure hp smart array p410i controller failure](https://www.techyparts.com/media/catalog/product/cache/1/image/9df78eab33525d08d6e5fb8d27136e95/84578/84578-598256-001_37879_base.jpg)
if problem persist, replace the cache module. There has been a fair amount of discussion on this and related topics. Re: drive array controller failure (slot 0) Hi nasprok Upgrading the firmware of HP Smart Array P410i controller to 6.60 (or higher) resolve the issue.
#HP SMART ARRAY P410I CONTROLLER FAILURE DRIVERS#
One other thought, it might be a good time to make sure your firmware and drivers are up-to-date.
#HP SMART ARRAY P410I CONTROLLER FAILURE MANUAL#
In the P410 manual it talks about using HP Systems Insight Manager. But I see no way of getting notification of a drive failure other than having to manually open the HP Array Configuration Utility software yourself. In /etc/apt/ è possibile creare un file hp. I installed an HP P410 RAID controller in my HP N40L ProLiant MicroServer. Be prepared and hopefully you'll never need to use it. Installando un sistema Linux Server, tipo Proxmox (Debian), è possibile monitorare lo stato di funzionamento del controller RAID hardware HP Smart Array P410i.
![hp smart array p410i controller failure hp smart array p410i controller failure](https://www.serverbasket.com/wp-content/uploads/2017/10/HPE-Smart-Array-P410-Controller.jpg)
Any time you're dealing with the drives, there is a potential for catastrophic failure.
#HP SMART ARRAY P410I CONTROLLER FAILURE UPDATE#
Update drivers with the largest database available. This controller is also available as a standalone PCIe card, the P410. Get the latest official Hewlett Packard (HP) Smart Array P410i Controller storage controller drivers for Windows 11, 10, 8.1, 8, 7, Vista, XP PCs. I've only had to replace one or two out of a few thousand systems over the years. It was the standard controller for G6 and G7 HP ProLiant servers and has a solid track record. Make sure you have verified backups of your data before attempting this process. The HP Smart Array P410 RAID controller is often embedded on the system board (known as the P410i). Although if the array was RAID 0 then a single drive failure would render all data lost.
![hp smart array p410i controller failure hp smart array p410i controller failure](http://pyatilistnik.org/wp-content/uploads/2014/12/Kak-nastroit-RAID-510-na-kontrollere-P410i-v-HP-dl380-g7-s-pomoshhyu-vstroennoy-utilityi-Option-ROM-Configuration-for-Arrays-ORCA-16.jpg)
If your array controller has battery (or flash) backed cache, you can just add the drive, expand the array, wait for the rebuild, and then extend the logical drive (E$). You would need to load up the HP Smart Storage Administrator to see the status of the RAID arrays on the server and get a better idea of what has happened.